The equipment used to conduct a load bank test produces artificial loads on the generator by bringing the engine to an appropriate operating.
Generator load bank testing cost.
Whether your generator is a 20kw or a 2 megawatt utilizing a load bank to test the generator s functionality will help detect.
Standard for emergency and standby power systems the national fire protection association s nfpa code 110 standard for emergency and standby power systems 2005 edition specifies load bank testing for epss as a requirement by law where.
In hospitals and other life safety situations the permanent generator may need to be tested up to 4 times a year.
For example if a generator is used as a backup for services associated with loss of life or serious injury such as in a hospital setting the testing requirements are much more frequent.
Reactive inductive load bank to test generators turbines backups or air conditioning systems at 0 8 power factor test loads of your power sources up to 3 000 kvar ideal for commercial or industrial duty.
Load bank testing involves firing up a standby or prime power generator and running it under an artificial load at its maximum capacity for a specified period of time.
Hard wiring the load bank for each test adds significant cost to an annual service agreement.
A load bank checks the engines ability to perform and provide the required horsepower when called upon in an emergency.
2 in lieu of nfpa 110 5 13 2 3 h i hook up the dry type load bank to generator and perform a stepped load test on the generator at 25 50 80 and 100 of the nameplate kw rating of the generator.
It is important to test your generator on a regular basis.
Each step to last fifteen 15 minutes record engine and generator data as detailed later in this section.
Generator load bank testing.
It verifies that all primary components of the generator set are in proper working condition under loaded conditions.
Saving time is especially important during urgent needs including medical testing screening centers and temporary hospitals.
Load bank testing is the process of using a mobile load bank to accurately mimic the operational load that a generator can achieve.
Power electrics use a load bank testing service to test your generator to its full capacity without disrupting the power supply to the building.
6 4 4 1 1 2 specifies that the 10 second criterion does not apply during the monthly testing of the generator.
Power system specialists recommend testing the generator systems once a year at full load with a load bank.
The frequency schedule for load bank testing on a generator often depends on how the generator is classified and what it is a standby for.